Before connecting the output actuators, we recommend to congure the parameters to suit your application (e.g. Can you issue a TC10 calibration certificate? 3. All information. The UT35A and UT32A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. - Modification of the product is strictly prohibited. IM 05C01E81-01EN 1 Edition Oct. 2014 st Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan internet site: www.yokogawa.com/ns Declaration of conformity and Manual retrieval TC10 is a panel mounting, Class II instrument. If so used, it is the user's responsibility to include in the system additional. The UT55A/UT52A also support open networks such as Ethernet communication. - Modification of the product is strictly prohibited. facilities, aviation facilities, and medical equipment. Pt 1000 calibration: According to EN 60751/A2. the protection provided by this instrument may be impaired. The UT32A-V,-C,-R is an easily configurable single-loop controller for 1/8 DIN sized. TC10-L is a panel mounting, Class II instrument. 2. suit your application (e.g. A ladder sequence function is included as standard. Can I hide the SP display? Such, applications include nuclear power equipment, devices using, radioactivity, railway facilities, aviation equipment, air navigation. that no power is being supplied to a cable to be connected. 1, This instrument is intended for permanent installation, for, indoor use only, in an electrical panel which encloses the. Supply Voltage: 100 to 240 VAC (-15 to +10%). Sometime, e.g. The TC10-L supports easy configuration for a quick start-up, and it is configurable as a high limit or low limit controller. The readout is updated every 15 minutes. 0 mA = 0 mBar and 20 mA = -1000 mBar (vacuum). The TC10-L is an FM approved limit controller that can be configured either as a high limit or as a low limit controller by a user. The following, Calls attention to actions or conditions that could cause serious or, fatal injury to the user or damage to the instrument, and indicates, precautions that should be taken to prevent such occurrences. To protect the AL2 and AL3 thresholds against, undesired changes, they are available only at "Parameters, list" level (password: 20). Notes: 1. - For control relay output, alarm relay output, and power terminal, L H C o R o D o F /GK Temperature Controller, NOTE about the structure of this document, The usual installation sequence is the reverse of the operator, During installation, the first step is the wiring procedure followed, by the complete configuration. SSR outputs are not isolated. Nadcap AMS2750F - What's New and How to Comply? Can I use the DI function to switch between auto/manual and between run stop/start? Yokogawa TC10 Temperature Controller Starting at $203.00 Select Options and Add to Cart View Company Reviews Manufactured By Yokogawa Includes FREE Ground Shipping on orders of $1,000 or more FREE Lifetime Tech Support Availability Usually ships in 2-3 weeks Product Manual Product Specs Overview Description Documents Accessories Features The UT75A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. YOKOGAWA Accessory Manuals 12 Devices / 14 Documents Full list of YOKOGAWA Accessory Manuals YOKOGAWA AC Power Distribution Manuals 1 Devices / 1 Documents YOKOGAWA Adapter Manuals 9 Devices / 10 Documents Select a mounting location having the following characteristics: 2. [34] r.md equal to 1(Limit output is de-energized at power on in any cases. The shallow depth of the controller helps save to space. A reinforced isolation must be assured by the external solid state relays. To protect the AL2 and AL3 thresholds against, undesired changes, they are available only at "Parameters, list" level (password: 20). Safety, Protection, and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. Select a mounting location having the following characteristics: 2. The SP value is not displayed if you dont specify a control operation. - Install the power cable keeping a distance of more than 1 cm from, - The power cable is required to meet the IEC standards concerned or the. 3.When a shielded cable is used, it should be connected at one point only. Use of the, instrument in a manner not prescribed herein may compromise, the product's functions and the protection features inherent in, the device. Such, applications include nuclear power equipment, devices using, radioactivity, railway facilities, aviation equipment, air navigation. I want to use the detailed parameter setting method of TC10, but what number is the password? When a TC input is selected and a decimal gure is programmed (see the next parameter) the max. TC10 TEMPERATURE CONTROLLER Engineering Manual Code: IM 05C01E81-02EN Third edition: Feb. 2018 Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns 1. 2.56 in min. Power supply:100 to 240 VAC (-15 to +10% of the nominal value); Power consumption: 6.0 VA max. For different configurations, see, Wattmeter (instantaneous power expressed in kW) (note 1), Wattmeter (Power consuption expressed in kWh/h) (note 2), Absolute worked time (expressed in days) (note 3), Absolute worked time (expressed in hours) (note 3), Notes: 1. Calibration: According to EN 60751/A2. There are no water or other uids (i.e. AL on the front of the TC10 is the alarm lamp. Yokogawa Electric Corporation for this Product in the EEA. The short depth of the controller helps save instrument panel space. The shallow depth of the controller helps to save instrument panel space. However, the instrument will only show the parameters applicable to its hardware options in accordance with the specic instrument conguration (i.e. Fsc allows the scaling of the analog input to set the maximum displayed/measured value. The TC10L features universal - input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. If this instrument is used in a manner not specified in this manual. We assume no liability for safety, or responsibility for the, product's quality, performance or functionality should users fail to. With thermocouple K input, can I display digits after the decimal point for the temperature? In other words the upper display will show: ]INP. be downloaded (free of charge) from the web-site: The Authorised Representative for this product in the EEA is: Viale Indipendenza 56, 27029 Vigevano (PV) - ITALY, The following general safety precautions must be observed during. When the upper display is showing a parameter and, Yokogawa Electric Corporation - TC10-L - ENGINEERING MANUAL - PAG. A long press allows you to close the conguration parameter procedure (the instrument will come back to the standard display). Relay output 2,3: 2A, 250 V AC, resistive load. condensation); 5. TC10 does not come with a terminal cover. 6. future reference. The shallow depth of the controller helps to save instrument panel space. 18 months (a year and a half) after shipment from the factory. Wattmeter Instantaneous power is continuously computed, as multiplication of the Load Voltage, Load Current parameter. The Yokogawa TC10 is a compact,all-in-one, single loop temperature controller with an easy-to-read, 3-color LED display. Set detailed parameter out group o1.F (output 1 function) = r.inP. Use a tester or similar device to ensure. The TC10 supports easy configuration for quick start-up, and itsPID allows for overshoot andundershoot control, so the end user can maintain a direct and constant temperature or accurate flow. I'm looking for a replacement for the UD310. The equipment wholly protected by double insulation or, - Whenever a failure or a malfunction of the device may cause dan-, gerous situations for persons, things or animals, please remember, that the plant must be equipped with additional devices which, - We warrant that the products will be free from defects in material. The output (OUT) display lamp is lit. Is there a controller to which I can connect a 2-wire Pt1000 sensor? Moreover, provide indication that the. Safety, Protection and Modification of the Product, - In order to protect the system controlled by this product and the, product itself, and to ensure safe operation, observe the safety, precautions described in the Engineering manual. Note: Every change of the dP parameter setting will produce. - Installation of protection and/or safety circuits with respect to a, lightning protector; protective equipment for the system control-, led by the product and the product itself; foolproof or failsafe de-, sign of a process or line using the system controlled by the product, or the product itself; and/or the design and installation of other, protective and safety circuits are to be appropriately implemented, Note: To leave the Configuration session without, - This product is not designed or manufactured to be used in critical, applications that directly affect or threaten human lives. codes: Cod1 [LMNO] for the Input Type and Control Mode selection and Cod2 [PQRS] for the Alarms and the Service Functions. 1. 5.3 HOW TO ENTER THE CONFIGURATION MODES. The EU Declaration of Conformity and the manual of the controller. equipment and devices that ensure personnel safety. Note: The group selection is cyclic as well as the selection of the parameters in a group. Input impedance:> 1 M. SKU:WE4537266 On burnout, it will be 0 mA. : 500W. The TC10-L features universal input, 3 Dynamic Colors Led Display two alarm outputs, retransmission output, a timer to count the total time the setpoint is exceeded, and a register to retain the maximum temperature reached. NOTE: This parameter will be shown only when a linear input has been selected (mV, V or mA). All information about the controller use can be found in the Engineering Manual: IM 05C01E81-12EN and the Communication Manual: IM 05C01E81-13EN and General Specification: GS 05C01E81-11EN. CONTROLLER Engineering Manual. setting AL1t [Alarm 1 type] to nonE [not used], all parameters related to alarm 1 will be skipped). The Yokogawa TC10-L is an all-in-one, FM approved limit controller with an easy-to-read, 3-color LED display. Select a mounting location having the following characteristics: 2.There is minimum vibrations and no impact; 4.There are no water or other uids (i.e. The 3-year warranty extends 36 months after shipment from our factory. 4.Pay attention to the line resistance; a high line resistance may cause measurement errors. 16 AWG or larger wires rated for at last 75C. SSR outputs are not isolated. There are no water or other fluids (i.e. The relative humidity is in accordance with the instrument. Push button for more than 3 seconds, the instrument will come back to the standard display. Worked Time counter is continuously increased when, Overall dimensions (L x H x D): 48 x 48 x 73 mm, This instrument is intended for permanent installation, for indoor. user must refer to the Engineering manual for special instructions. [13] AL1 and [30] AL2 will be forced to : for an absolute maximum alarm, them will be forced to the maximum input span, for an absolute minimum alarm, them will be forced to the minimum input span, for all other alarm, them will be forced to zero, [14] HAL1 and [31] HAL2 will be forced equal to the 0.5% of the input span, [35] HYS will be forced equal to 0.05 % of the input span, the CAL group will be reset [51]A.L.P, [52] A.L.O, [53] A.H.P, [54] A.H.O. when you re-congure an instrument previously used for other works or from other people or when you have made too many errors during conguration and you decided to re-congure the instrument, it is possible to restore the factory conguration. Products and components that are subject to wear due to conditions. Yokogawa TC10 Manual Download for 1 TC10 TEMPERATURE CONTROLLER Engineering Manual Code: IM 05C01E81-02EN Third edition: Feb. 2018 Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan www.yokogawa.com/ns 1. - Installation of protection and/or safety circuits with respect to a, lightning protector; protective equipment for the system controlled, by the product and the product itself; foolproof or failsafe design, of a process or line using the system controlled by the product or, the product itself; and/or the design and installation of other, protective and safety circuits are to be appropriately implemented, - This product is not designed or manufactured to be used in critical, applications that directly affect or threaten human lives. We assume no liability for safety, or responsibility for, the product's quality, performance or functionality should users. The ambient temperature is in accordance with the operative, 6. For different configurations, see, Wattmeter (instantaneous power expressed in kW) (note 1), Wattmeter (Power consuption expressed in kWh/h) (note 2), Absolute worked time (expressed in days) (note 3), Absolute worked time (expressed in hours) (note 3), Notes: 1. Every group denes all parameters related with a specic function (e.g. 1. The ambient temperature is in accordance with the operative, 6. IM 05C01E81-01EN, 2-9-32 Nakacho, Musashino-shi, Tokyo 180-8750 Japan, EU Declaration of conformity and Manual retrieval, TC10 is a panel mounting, Class II instrument. There is minimum vibrations and no impact; 4. Use of the, instrument in a manner not prescribed herein may compromise, the product's functions and the protection features inherent in, the device. displayed value becomes 999.9C or 999.9F. Case: Plastic, self-extinguishing degree: V-0 according to UL 94; Front protection: IP 65 (when the optional panel gasket is mounted) for indoor locations according to EN 60070-1; Terminals protection: IP 20 according to EN 60070-1; Terminal block: 16 screw terminals for cables of. observe these instructions when operating the product. Moreover, provide indication that the. - For control relay output, alarm relay output, and power terminal. The. I selected SP value transmission on TC10, but no SP value is displayed. (100 to 240 VAC), Insulation voltage: 2300 V rms according to EN 61010-1, Front protection: IP 65 (when the optional panel gasket is mounted), Accessories: Mounting bracket, Quick Guide, Operative Modes: Auto / Manual / Stand-by (force control output to zero), Serial Communication (optional): RS-485 MODBUS, PID control with single or double action with overshoot control (Fuzzy overshoot control), ON/OFF, ON/OFF Neutral Zone, Auto-tuning, and Self-tuning. The UT55A and UT52A temperature controllers employ an easy-to-read, 14-segment large color LCD display, along with navigation keys, thus greatly increasing the monitoring and operating capabilities. There is no parameter for specifying the output direction. 2.It is possible to set a initial scale read-out higher than the full scale read-out in order to obtain a reverse read-out scaling.